Search results
Results from the WOW.Com Content Network
The LVAD is the most common device applied to a defective heart (it is sufficient in most cases; the right side of the heart is then often able to make use of the heavily increased blood flow), but when the pulmonary arterial resistance is high, then an (additional) right ventricular assist device (RVAD) might be necessary to resolve the ...
The pump was designed to allow for temporary support of a dying heart. It is a continuous flow pump, it does not need to be synced to the rhythm of the heart. It assists in temporary heart stimulation with conditions such as cardiogenic shock following acute myocardial infarction, heart failure from cardio pulmonary bypass, and more. The pump ...
Impella heart pumps are percutaneous microaxial pumps that act as mechanical circulatory support devices in patients in need of hemodynamic support. [11] The pumps are mounted on support catheters and typically inserted through the femoral artery, although axillary and subclavian artery approaches are not uncommon. [12]
Cardiac resynchronisation therapy (CRT or CRT-P) is the insertion of electrodes in the left and right ventricles of the heart, as well as on occasion the right atrium, to treat heart failure by coordinating the function of the left and right ventricles via a pacemaker, a small device inserted into the anterior chest wall.
Berlin Heart GmbH is a German company that develops, produces and markets ventricular assist devices (VADs). The devices mechanically support the hearts of patients with end-stage heart failure. Berlin Heart's products include the implantable INCOR VAD and the paracorporeal EXCOR VAD. To date, Berlin Heart produces the only device of its kind ...
The FDA approved the CardiAssist ECP system for the treatment of angina, acute myocardial infarction and cardiogenic shock under a 510(k) submission in 1980 [1] [failed verification] Since then, additional ECP devices have been cleared by the FDA for use in treating stable or unstable angina pectoris, acute myocardial infarction, cardiogenic shock, and congestive heart failure.
During a protected percutaneous coronary intervention (Protected PCI) procedure, "the Impella 2.5 heart pump helps maintain a stable heart function by pumping blood for the heart. This gives a weak heart muscle an opportunity to rest and reduces the heart’s workload, preventing the heart from being overstressed by the procedure as coronary ...
Cardiogenic shock is caused by the failure of the heart to pump effectively. It is due to damage to the heart muscle , most often from a heart attack or myocardial contusion . [ 6 ] Other causes include abnormal heart rhythms , cardiomyopathy , heart valve problems, ventricular outflow obstruction (i.e. systolic anterior motion in hypertrophic ...