Ads
related to: anode stuck in water heater pipe fittings removal procedure
Search results
Results from the WOW.Com Content Network
Heat traps are valves or loops of pipe on the cold water inlet and hot water outlet of water heaters. The heat traps allow cold water to flow into the water heater tank, but prevent unwanted natural convection and heated water to flow out of the tank. [1] [2] Newer water heaters have built-in heat traps.
Over time the galvanic anode continues to corrode, consuming the anode material until eventually it must be replaced. Galvanic or sacrificial anodes are made in various shapes and sizes using alloys of zinc, magnesium, and aluminum. ASTM International publishes standards on the composition and manufacturing of galvanic anodes. [10] [11] [12]
Anodic protection (AP) otherwise referred to as Anodic Control is a technique to control the corrosion of a metal surface by making it the anode of an electrochemical cell and controlling the electrode potential in a zone where the metal is passive.
In brief, corrosion is a chemical reaction occurring by an electrochemical mechanism (a redox reaction). [1] During corrosion of iron or steel there are two reactions, oxidation (equation 1), where electrons leave the metal (and the metal dissolves, i.e. actual loss of metal results) and reduction, where the electrons are used to convert oxygen and water to hydroxide ions (equation 2): [2]
The actual attack on the metal is by the corrosive action of the water to which it is exposed while the erosive factor is the mechanical removal of the corrosion product from the surface. Impingement attack produces highly characteristic water-swept pits, which are often horseshoe shaped, or it can produce broader areas of attack.
Key Seated Stuck Pipe. Key seating occurs when the drill string becomes off-centered in the wellbore, and the pipe collars become caught on a deviation in the wellbore. If the rig is able to move the drill string freely downhole, but every time the drill string is pulled upward it becomes stuck at the same point, then it is likely that the pipe ...
Electrically insulate the two metals from each other. If they are not in electrical contact, no galvanic coupling will occur. This can be achieved by using non-conductive materials between metals of different electropotential. Piping can be isolated with a spool of pipe made of plastic materials, or made of metal material internally coated or ...
There are two types of surface blowdown fittings. The simpler is a pipe entering the steam drum at the normal water level. A more sophisticated skimmer arrangement attaches a swivel joint to the pipe for a short length of pipe suspended by a float. [2] The skimmer may be more effective at removing floating oil which might otherwise cause foaming.
Ads
related to: anode stuck in water heater pipe fittings removal procedure