enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Purging (gas) - Wikipedia

    en.wikipedia.org/wiki/Purging_(gas)

    Because an inert purge gas is used, the purge procedure may (erroneously) be referred to as inerting in everyday language. This confusion may lead to dangerous situations. Carbon dioxide is a safe inert gas for purging. Carbon dioxide is an unsafe inert gas for inerting, as it may ignite the vapors and result in an explosion. [2]

  3. Inerting system - Wikipedia

    en.wikipedia.org/wiki/Inerting_system

    The inerting systems will probably prevent 8 of those 9 probable explosions, the FAA said. Before the inerting system rule was proposed, Boeing stated that it would install its own inerting system on airliners it manufactures beginning in 2005. Airbus had argued that its planes' electrical wiring made the inerting system an unnecessary expense.

  4. Inert gas - Wikipedia

    en.wikipedia.org/wiki/Inert_gas

    Inert gas can also be used to purge the tank of the volatile atmosphere in preparation for gas freeing - replacing the atmosphere with breathable air - or vice versa. The flue gas system uses the boiler exhaust as its source, so it is important that the fuel/air ratio in the boiler burners is properly regulated to ensure that high-quality inert ...

  5. Inerting (gas) - Wikipedia

    en.wikipedia.org/wiki/Inerting_(gas)

    The flammability limits of the gas define those proportions, i.e. the ignitable range. In combustion engineering terms, the admission of inert gas can be said to dilute the oxygen below the limiting oxygen concentration. Inerting differs from purging. Purging, by definition, ensures that an ignitable mixture never forms. Inerting makes an ...

  6. Schlenk line - Wikipedia

    en.wikipedia.org/wiki/Schlenk_line

    This is where a cannula needle, which is connected to the inert gas on the line, is inserted into the reaction vessel containing the solvent; this effectively bubbles the inert gas into the solution, which will actively push out trapped gas molecules from the solvent. [5] Filtration under inert conditions poses a special challenge.

  7. Air purge system - Wikipedia

    en.wikipedia.org/wiki/Air_purge_system

    An air purge heating unit is used to ensure that the purge air remains at a temperature above the acid dew-point. This temperature is typically around 20 °C/68 °F. [2] If temperatures are below this point, the controls will be corroded by condensation of compounds in the flue gas. Heated air ensures that controls are dry during startup. [3]

  8. Gas bubbler - Wikipedia

    en.wikipedia.org/wiki/Gas_bubbler

    A gas bubbler is a piece of laboratory glassware which consists of a glass bulb filled with a small amount of fluid—usually mineral or silicone oil, less commonly mercury. The inlet to the bulb is connected to a ground glass joint, while the outlet is vented to the air. Gas bubblers are used to exclude air from a reaction or a system.

  9. Tank blanketing - Wikipedia

    en.wikipedia.org/wiki/Tank_blanketing

    Since most blanketing gas sources will provide gas at a much higher than desired pressure, a blanketing system will also use a pressure reducing valve to decrease the inlet pressure to the tank. Although it varies from application to application, blanketing systems usually operate at a slightly higher than atmospheric pressure (a few inches of ...