enow.com Web Search

  1. Ads

    related to: fire extinguisher using method of testing for electrical heat loss due to chemical

Search results

  1. Results from the WOW.Com Content Network
  2. Purple-K - Wikipedia

    en.wikipedia.org/wiki/Purple-K

    Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemical fire extinguishers. [1] It is the second most effective dry chemical in fighting class B (flammable liquid) fires after Monnex (potassium allophanate), and can be used against some energized electrical equipment fires (USA class C fires). [2]

  3. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.

  4. Fire control - Wikipedia

    en.wikipedia.org/wiki/Fire_control

    For example, using a type A, B, C fire extinguisher on a chemical fire will do the opposite of what the extinguisher is supposed to do and can cause an explosion. The different types of fire extinguishers include CO 2 fire extinguishers, type A, B, or C carbon dioxide fire extinguishers, dry chemical powder extinguishers, and water-based fire ...

  5. Condensed aerosol fire suppression - Wikipedia

    en.wikipedia.org/wiki/Condensed_aerosol_fire...

    It is similar to but not identical to dry chemical fire extinction methods, using an innovative pyrogenic, condensed aerosol fire suppressant. It is a highly effective fire suppression method for class A, B, C, E and F (as is the case for most fire-extinguishing agents, it is not applicable to metal fires – class D). [ 1 ]

  6. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    A stored-pressure fire extinguisher. A fire extinguisher is a handheld active fire protection device usually filled with a dry or wet chemical used to extinguish or control small fires, often in emergencies.

  7. Bromochlorodifluoromethane - Wikipedia

    en.wikipedia.org/wiki/Bromochlorodifluoromethane

    Bromochlorodifluoromethane (BCF), also referred to by the code numbers Halon 1211 and Freon 12B1, is a haloalkane with the chemical formula C F 2 Cl Br.It is used for fire suppression, especially for expensive equipment or items that could be damaged by the residue from other types of extinguishers. [1]

  8. Gaseous fire suppression - Wikipedia

    en.wikipedia.org/wiki/Gaseous_fire_suppression

    Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.

  9. Halotron I - Wikipedia

    en.wikipedia.org/wiki/Halotron_I

    The test was conducted at UL, and showed that Halotron I offered similar effectiveness as Halon 1211, but with significantly less harm to both humans and the environment. [4] However, achieving the same fire suppression ratings require a higher volume of Halotron I compared to Halon 1211.

  1. Ads

    related to: fire extinguisher using method of testing for electrical heat loss due to chemical