Search results
Results from the WOW.Com Content Network
Concrete is poured around these plastic forms to create internal voids in the slab A voided biaxial slab installation in Turkey. Voided biaxial slabs, sometimes called biaxial slabs or voided slabs, are a type of reinforced concrete slab which incorporates air-filled voids to reduce the volume of concrete required.
A prestressing system utilising tendons with single strands, or tendons able to be tensioned using a mono-strand jack. [2]: 12 mono-strand jack A tensioning jack that applies force to a single tendon strand at a time. multi-strand A prestressing system utilising tendons with multiple strands, and are tensioned using a multi-strand jack. [2]: 13
Beam and block is a construction method to support flooring, especially for ground floors as well as multi story buildings. [1] It is made of cast concrete , one piece of which is a prestressed concrete beam , which can be an inverted T-shaped beam, or lintel, the other piece being a simple rectangular block. [ 1 ]
The tremie concrete placement method uses a vertical or nearly vertical pipe, through which concrete is placed by gravity feed below water level. [4]The lower end of the pipe is kept immersed in fresh concrete so that concrete rising from the bottom displaces the water above it, thus limiting washing out of the cement content of the fresh concrete at the exposed upper surface.
By 1963, a new structural system of framed tubes had appeared in skyscraper design and construction. Fazlur Rahman Khan, a structural engineer from Bangladesh (then called East Pakistan) who worked at Skidmore, Owings & Merrill, defined the framed tube structure as "a three dimensional space structure composed of three, four, or possibly more frames, braced frames, or shear walls, joined at or ...
Concrete spalling from the ceiling of an office unit (interior) in Singapore, possibly due to rebar corrosion. Reinforced concrete can fail due to inadequate strength, leading to mechanical failure, or due to a reduction in its durability. Corrosion and freeze/thaw cycles may damage poorly designed or constructed reinforced concrete.
A precast concrete walled house under construction An example of low-quality precast concrete with exposed dowels, connectors, indications of cracks, and malformations, even during its installation, Barangay Lantic, Carmona, Cavite, Philippines Interior view of the walls, supports, and roof of a precast commercial shop in Williston, North Dakota, US.
The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...