Eddy current sensors are displacement sensors that use the principle of eddy current formation to sense displacement. These sensors measure shaft displacement in rotating machinery and have been around for many years as they offer manufacturers high-linearity, high-speed measurements, and high resolution. [ 1 ]
ISO 14617 Graphical symbols for diagrams is a library of graphical symbols for diagrams used in technical applications. [1] ISO 14617 consists of the following parts: Part 1: General information and indexes; Part 2: Symbols having general application; Part 3: Connections and related devices; Part 4: Actuators and related devices
The term alternating current applies to a voltage vs. time function that is sinusoidal with a frequency f. When it is applied to a typical (linear time-invariant) circuit or device, it causes a current that is also sinusoidal. In general there is a constant phase difference φ between any two sinusoids. The input sinusoidal voltage is usually ...
A zero crossing detector is a comparator with the reference level set at zero. It is used for detecting the zero crossings of AC signals. It is used for detecting the zero crossings of AC signals. It can be made from an operational amplifier with an input voltage at its positive input (see circuit diagram) [ clarification needed ] .
The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect current sensor; the only difference is that this method uses the saturable inductor instead of the Hall-effect sensor in the air gap. Saturable inductor current sensor is based on the detection of an inductance change. The saturable inductor is ...
Each symbol is encoded as a different combination of amplitude and phase of the carrier, so each symbol is represented by a point on the constellation diagram, called a constellation point. The constellation diagram shows all the possible symbols that can be transmitted by the system as a collection of points.
The technique is very sensitive and can detect tight cracks. Surface inspection can be performed both on ferromagnetic and non-ferromagnetic materials. [8] [9] Tubing inspection is generally limited to non-ferromagnetic tubing and is known as conventional eddy current testing.
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...