Atmospheric pressure chemical ionization chamber cross section. Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (10 5 Pa), [1] [2] commonly coupled with high-performance liquid chromatography (HPLC). [3]
The use of the term mass spectroscopy is now discouraged due to the possibility of confusion with light spectroscopy. [1] [8] Mass spectrometry is often abbreviated as mass-spec or simply as MS. [1] Modern techniques of mass spectrometry were devised by Arthur Jeffrey Dempster and F.W. Aston in 1918 and 1919 respectively.
Mass spectrometry imaging (MSI) is a technique used in mass spectrometry to visualize the spatial distribution of molecules, as biomarkers, metabolites, peptides or proteins by their molecular masses. After collecting a mass spectrum at one spot, the sample is moved to reach another region, and so on, until the entire sample is scanned.
Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is a high-resolution technique that can be used to determine masses with high accuracy. Many applications of FTICR-MS use this mass accuracy to help determine the composition of molecules based on accurate mass. This is possible due to the mass defect of the elements.
This design effectively provides robust interfacing with mass spectrometry and addresses the reproducibility challenges associated with previous designs. This porous emitter interface has been explored to couple of CITP/CZE (or transient ITP ) which greatly improves sample loading capacity of CE and enabled ultrasensitive detection of trace ...
Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples at atmospheric conditions. Coupled ionization sources-MS systems are popular in chemical analysis because the individual capabilities of various sources combined with different MS systems ...
In laser microprobe mass analysis, a highly focused laser beam is pulsed on a micro sample usually with a volume of approximately 1 microliter. The resulting ions generated by this laser are then analyzed with time-of-flight mass spectrometry to give composition, concentration, and in the case of organic molecules structural information.
Both, the first mass analyzer and the collision cell are continuously exposed to ions from the source, in a time independent manner. [4] It is once the ions move into the third mass analyzer that time dependence becomes a factor. [4] The first quadrupole mass filter, Q1, is the primary m/z selector after the sample leaves the ionization source.