Results from the WOW.Com Content Network
A remote terminal unit (RTU) is a microprocessor-controlled electronic device that interfaces objects in the physical world to a distributed control system or SCADA (supervisory control and data acquisition) system by transmitting telemetry data to a master system, and by using messages from the master supervisory system to control connected objects. [1]
The DNP3 protocol is also referenced in IEEE Std. IEEE 1379-2000, which recommends a set of best practices for implementing modern SCADA Master-RTU/IED communication links. These include not just encryption but other practices that enhance security against well known intrusion methods.
SCADA protocols are designed to be very compact. Many are designed to send information only when the master station polls the RTU. Typical legacy SCADA protocols include Modbus RTU, RP-570, Profibus and Conitel. These communication protocols, with the exception of Modbus (Modbus has been made open by Schneider Electric), are all SCADA-vendor ...
A SCADA system uses remote terminal units (RTUs) to send supervisory data back to a control centre. Most RTU systems always had some capacity to handle local control while the master station is not available. However, over the years RTU systems have grown more and more capable of handling local control.
Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server. [2]
However, the development of SCADA (supervisory control and data acquisition) systems allowed remote control and monitoring of electrical plant from centralised control centres. Initially individual SCADA manufacturers developed their own proprietary "closed" protocols for communicating from a control centre to electrical equipment in the field.
The security of IEC 104, by design has been proven to be problematic, [2] as many of the other SCADA protocols developed around the same time. Though the IEC technical committee (TC) 57 have published a security standard IEC 62351 , which implements encryption tunneling and network monitoring in an effort to address attacks such as packet ...
Modbus RTU or ASCII or TCP; oBIX - Open Building Information Exchange is a standard for RESTful Web Services-based interfaces to building control systems developed by OASIS. UPB - 2-way Peer to Peer Protocol; VSCP - Very Simple Control Protocol is a free protocol with main focus on building- or home-automation; xAP – Open protocol