  1. Results from the WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  3. Orders of magnitude (current) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(current)

    400 V low voltage secondary side distribution transformer with primary 12 kV; 200 kVA (up to 1000 kVA also common) [7] 10 3: 2 kA 10.5 kV secondary side from an electrical substation with primary 115 kV; 63 MVA [8] 9.3 kA 2.7V, Ultracapacitor short circuit current [9] 10 4: 25 kA Lorentz force can crusher pinch [10] 30 kA Typical lightning ...

  4. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    The volt-ampere (SI symbol: VA, [1] sometimes V⋅A or V A) is the unit of measurement for apparent power in an electrical circuit.It is the product of the root mean square voltage (in volts) and the root mean square current (in amperes). [2]

  5. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power Quality Analyzers, often referred to as Power Analyzers, make a digital recording of the voltage and current waveform (typically either one phase or three phase) and accurately calculate true power (watts), apparent power (VA) power factor, AC voltage, AC current, DC voltage, DC current, frequency, IEC61000-3-2/3-12 Harmonic measurement ...

  6. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    Set sizes range from 8 to 30-kW (also 8 to 30-kVA single phase) for homes, small shops, and offices, with the larger industrial generators from 8-kW (11 kVA) up to 2,000-kW (2,500-kVA three phase) used for office complexes, factories, and other industrial facilities. A 2,000-kW set can be housed in a 40 ft (12 m) ISO container with a fuel tank ...

  7. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    The mid-size stationary engine–generator pictured here is a 100 kVA set which produces 415 V at around 110 A. It is powered by a 6.7-liter turbocharged Perkins Phaser 1000 Series engine, and consumes approximately 27 liters of fuel an hour, on a 400-liter tank.

  8. Generator (circuit theory) - Wikipedia

    en.wikipedia.org/wiki/Generator_(circuit_theory)

    A generator in electrical circuit theory is one of two ideal elements: an ideal voltage source, or an ideal current source. [1] These are two of the fundamental elements in circuit theory. Real electrical generators are most commonly modelled as a non-ideal source consisting of a combination of an ideal source and a resistor.

  9. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.