enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Evans balance - Wikipedia

    en.wikipedia.org/wiki/Evans_balance

    An Evans balance, also known as a Johnson Matthey magnetic susceptibility balance, is a scientific instrument used to measure the magnetic susceptibility of solids and liquids. [ 1 ] [ 2 ] Magnetic susceptibility quantifies the extent to which a material becomes magnetized in an applied magnetic field .

  3. Gouy balance - Wikipedia

    en.wikipedia.org/wiki/Gouy_balance

    Schematic diagram of Gouy balance. The Gouy balance, invented by the French physicist Louis Georges Gouy, is a device for measuring the magnetic susceptibility of a sample. . The Gouy balance operates on magnetic torque, by placing the sample on a horizontal arm or beam suspended by a thin fiber, and placing either a permanent magnet or electromagnet on the other end of the arm, there is a ...

  4. Vibrating-sample magnetometer - Wikipedia

    en.wikipedia.org/wiki/Vibrating-sample_magnetometer

    The alternating magnetic field induces an electric field in the pickup coils of the VSM. [4] The current is proportional to the magnetization of the sample - the greater the induced current, the greater the magnetization. As a result, typically a hysteresis curve will be recorded [5] and from there the magnetic properties of the sample can be ...

  5. Hall effect sensor - Wikipedia

    en.wikipedia.org/wiki/Hall_effect_sensor

    Hall effect magnetometers (also called tesla meters or gauss meters) use a Hall probe [23] with a Hall element to measure magnetic fields or inspect materials (such as tubing or pipelines) using the principles of magnetic flux leakage. A Hall probe is a device that uses a calibrated Hall effect sensor to directly measure the strength of a ...

  6. Faraday balance - Wikipedia

    en.wikipedia.org/wiki/Faraday_balance

    An alternative method for measuring magnetic susceptibility is the Gouy balance. In this technique there is an inhomogeneous magnetic field in the central region between two (flat) poles of a magnet, either a permanent magnet or an electromagnet. The sample must be in powder form and is placed in a cylindrical tube, which is then suspended in ...

  7. Ball-pen probe - Wikipedia

    en.wikipedia.org/wiki/Ball-pen_probe

    where is measured by the ball-pen probe, by the standard Langmuir probe, and is given by the Langmuir probe geometry, plasma gas composition, the magnetic field, and other minor factors (secondary electron emission, sheath expansion, etc.). It can be calculated theoretically, its value being about 3 for a non-magnetized hydrogen plasma.

  8. Leeb rebound hardness test - Wikipedia

    en.wikipedia.org/wiki/Leeb_rebound_hardness_test

    The quotient 1000×v r /v i is quoted in the Leeb rebound hardness unit HLx (where x indicates the probe and impact body type: D, DC, DL, C, G, S, E) . [ 1 ] [ 3 ] While in the traditional static tests the test force is applied uniformly with increasing magnitude, dynamic testing methods apply an instantaneous load.

  9. Ferromagnetic resonance - Wikipedia

    en.wikipedia.org/wiki/Ferromagnetic_resonance

    Ferromagnetic resonance was experimentally discovered by V. K. Arkad'yev when he observed the absorption of UHF radiation by ferromagnetic materials in 1911. A qualitative explanation of FMR along with an explanation of the results from Arkad'yev was offered up by Ya. G. Dorfman in 1923, when he suggested that the optical transitions due to Zeeman splitting could provide a way to study ...