enow.com Web Search

  1. Ads

    related to: lagging power factor means that water is broken free movie download

Search results

  1. Results from the WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  3. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    An over-excited synchronous motor has a leading power factor. This makes it useful for power-factor correction of industrial loads. Both transformers and induction motors draw lagging (magnetising) currents from the line. On light loads, the power drawn by induction motors has a large reactive component and the power factor has a low value. The ...

  4. Synchronous motor - Wikipedia

    en.wikipedia.org/wiki/Synchronous_motor

    This ability to selectively control power factor can be exploited for power factor correction of the power system to which the motor is connected. Since most power systems of any significant size have a net lagging power factor, the presence of overexcited synchronous motors moves the system's net power factor closer to unity, improving efficiency.

  5. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...

  6. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    Power factor correcting capacitors can be added externally to neutralize a constant amount of the variable reactive excitation current. After starting, an induction generator can use a capacitor bank to produce reactive excitation current, but the isolated power system's voltage and frequency are not self-regulating and destabilize readily.

  7. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  8. Zero power factor curve - Wikipedia

    en.wikipedia.org/wiki/Zero_power_factor_curve

    The zero power factor curve (also zero power factor characteristic, ZPF, ZPFC) of a synchronous generator is a plot of the output voltage as a function of the excitation current or field using a zero power factor (purely inductive) load that corresponds to rated voltage at rated current (1 p.u.).

  9. Kill A Watt - Wikipedia

    en.wikipedia.org/wiki/Kill_A_Watt

    The low power factor means that the DRSSTC was drawing awful peak currents, but the two meters still agreed well. I conclude that the Prodigit wattmeter sold by Maplin works fine for Tesla coiling. It also seems to be fairly resistant to RFI, although I didn't let the coil arc to ground heavily.

  1. Ads

    related to: lagging power factor means that water is broken free movie download