enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Optical microscope - Wikipedia

    en.wikipedia.org/wiki/Optical_microscope

    Adjustment knobs move the stage up and down with separate adjustment for coarse and fine focusing. The same controls enable the microscope to adjust to specimens of different thickness. In older designs of microscopes, the focus adjustment wheels move the microscope tube up or down relative to the stand and had a fixed stage. [citation needed]

  3. Traveling microscope - Wikipedia

    en.wikipedia.org/wiki/Traveling_microscope

    A traveling microscope. E—eyepiece, O—objective, K—knob for focusing, V—vernier, R—rails, S—screw for fine position adjustment. A travelling microscope is an instrument for measuring length with a resolution typically in the order of 0.01mm.

  4. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.

  5. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    The focus of the first lens is traditionally about 2mm away from the plane face coinciding with the sample plane. A pinhole cap can be used to align the optical axis of the condenser with that of the microscope. The Abbe condenser is still the basis for most modern light microscope condenser designs, even though its optical performance is poor.

  6. Near-field scanning optical microscope - Wikipedia

    en.wikipedia.org/wiki/Near-field_scanning...

    The near-field optical (NFO) microscope involved a sub-wavelength aperture at the apex of a metal coated sharply pointed transparent tip, and a feedback mechanism to maintain a constant distance of a few nanometers between the sample and the probe. Lewis et al. were also aware of the potential of an NFO microscope at this time. [14]

  7. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.

  8. Oil immersion - Wikipedia

    en.wikipedia.org/wiki/Oil_immersion

    The resolution of a microscope is defined as the minimum separation needed between two objects under examination in order for the microscope to discern them as separate objects. This minimum distance is labelled δ. If two objects are separated by a distance shorter than δ, then they will appear as a single object in the microscope.

  9. Inverted microscope - Wikipedia

    en.wikipedia.org/wiki/Inverted_microscope

    An inverted microscope is a microscope with its light source and condenser on the top, above the stage pointing down, while the objectives and turret are below the stage pointing up. It was invented in 1850 by J. Lawrence Smith , a faculty member of Tulane University (then named the Medical College of Louisiana).