Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...
Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .
The Gran plot is based on the Nernst equation which can be written as = + {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.
The connection can be direct, through a narrow tube to reduce mixing, or through a salt bridge, depending on the other electrode and solution. This creates an ionically conductive path to the working electrode of interest. A reference electrode is an electrode that has a stable and well-known electrode potential.
A redox indicator (also called an oxidation-reduction indicator) is an indicator which undergoes a definite color change at a specific electrode potential. The requirement for fast and reversible color change means that the oxidation-reduction equilibrium for an indicator redox system needs to be established very quickly. Therefore, only a few ...
In order to accurately measure the potential difference between the two sides of the glass membrane reference electrode, typically a silver chloride electrode or calomel electrode are required on each side of the membrane. Their purpose is to measure changes in the potential on their respective side.
Whether the analyte is reduced or oxidized depends on the analyte and the potential applied, but its reaction always occurs at the working/indicator electrode. Therefore, the working electrode potential varies as a function of the analyte concentration. A second auxiliary electrode completes the electric circuit, called the counter electrode.