Search results
Results from the WOW.Com Content Network
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
These checkweighers are known also as belt weighers, in-motion scales, conveyor scales, dynamic scales, and in-line scales. In filler applications, they are known as check scales. Typically, there are three belts or chain beds: An infeed belt that may change the speed of the package and to bring it up or down to a speed required for weighing.
A PMCS check is required before, during, and after a piece of equipment or vehicle is used. Checks are also done at weekly, monthly, semi-annual, annual, or bi-annual intervals, depending on the specific part. [1] Doing a PMCS check every time equipment is used may reduce the number of failures.
The grooves decrease in depth from one end of the block to the other, according to a scale stamped next to them. A typical Hegman gauge is 170mm by 65mm by 15mm, with a channel of grooves running lengthwise, 12.5mm across and narrowing uniformly in depth from 100 μm to zero and used to determine particle size .
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
manual or electronic; manufacturer; Irrespective of brand or expense of pipette, every micropipette manufacturer recommends checking the calibration at least every six months, if used regularly. Companies in the drug or food industries are required to calibrate their pipettes quarterly (every three months).
Although "International Temperature Scale of 1990" has the word "scale" in its title, this is a misnomer that can be misleading. The ITS-90 is not a scale; it is an equipment calibration standard. Temperatures measured with equipment calibrated per ITS-90 may be expressed using any temperature scale such as Celsius, Kelvin, Fahrenheit, or Rankine.
Calibration is generally accomplished through means of gravimetric analysis. This entails dispensing samples of distilled water into a receiving vessel perched atop a precision analytical balance. The density of water is a well-known constant, and thus the mass of the dispensed sample provides an accurate indication of the volume dispensed.