  1. Results from the WOW.Com Content Network
  2. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...

  3. Oxygenated treatment - Wikipedia

    en.wikipedia.org/wiki/Oxygenated_treatment

    With oxygenated treatment, oxygen is injected into the feedwater to keep the oxygen level between 30 and 50 ppb. OT programs are most commonly used in supercritical (i.e. >3250psi) power boilers. The ability to change an existing sub-critical boiler over to an OT program is very limited.

  4. Feedwater heater - Wikipedia

    en.wikipedia.org/wiki/Feedwater_heater

    An economizer serves a similar purpose to a feedwater heater, but is technically different as it does not use cycle steam for heating. In fossil-fuel plants, the economizer uses the lowest-temperature flue gas from the furnace to heat the water before it enters the boiler proper. This allows for the heat transfer between the furnace and the ...

  5. Industrial water treatment - Wikipedia

    en.wikipedia.org/wiki/Industrial_water_treatment

    Two of the main processes of industrial water treatment are boiler water treatment and cooling water treatment. A large amount of proper water treatment can lead to the reaction of solids and bacteria within pipe work and boiler housing. Steam boilers can suffer from scale or corrosion when left untreated. Scale deposits can lead to weak and ...

  6. Deaerator - Wikipedia

    en.wikipedia.org/wiki/Deaerator

    The treated water falls into a storage tank below the deaerator. [20] [3] Oxygen scavenging chemicals are very often added to the deaerated boiler feedwater to remove any last traces of oxygen that were not removed by the deaerator. The type of chemical added depends on whether the location uses a volatile or non-volatile water treatment program.

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).

  8. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.

  9. Forced circulation boiler - Wikipedia

    en.wikipedia.org/wiki/Forced_circulation_boiler

    In a water tube boiler, the water is recirculated inside until the vapor pressure of the water overcomes the vapor pressure inside the stream drum and becomes saturated steam. The forced circulation boiler begins the same as a natural circulation boiler, at the feed water pump. Water is introduced into the steam drum and is circulated around ...