Search results
Results from the WOW.Com Content Network
A Doppler fetal monitor, informally known as sonicaid (generic trademark), is a hand-held ultrasound transducer used to detect the fetal heartbeat for prenatal care. It uses the Doppler effect to provide an audible simulation of the heart beat. Some models also display the heart rate in beats per minute (BPM).
A Zigzag pattern of fetal heart rate (FHR) is defined as FHR baseline amplitude changes of more than 25 beats per minute (bpm) with a minimum duration of 2 minutes and maximum of 30 minutes. [19] However, according to another study, even a >1 min duration of the zigzag pattern is associated with an increased risk of adverse neonatal outcomes. [21]
The presence of these biophysical variables implies absence of significant central nervous system hypoxemia/acidemia at the time of testing. By comparison, a compromised fetus typically exhibits loss of accelerations of the fetal heart rate (FHR), decreased body movement and breathing, hypotonia, and, less acutely, decreased amniotic fluid volume.
Some resources indicate that there are clear reasons for this and that such scans are also clearly beneficial because ultrasound enables clear clinical advantages for assessing the developing fetus in terms of morphology, bone shape, skeletal features, fetal heart function, volume evaluation, fetal lung maturity, [21] and general fetus well being.
Echogenic intracardiac focus (EIF) is a small bright spot seen in the baby's heart on an ultrasound exam. This is thought to represent mineralization, or small deposits of calcium, in the muscle of the heart. EIFs are found in about 3–5% of normal pregnancies and cause no health problems. EIFs themselves have no impact on health or heart ...
Doppler fetal monitors, although usually not technically -graphy but rather sound-generating, use the Doppler effect to detect the fetal heartbeat for prenatal care. These are hand-held, and some models also display the heart rate in beats per minute (BPM). Use of this monitor is sometimes known as Doppler auscultation.
During uterine contractions, fetal oxygenation is worsened. Late decelerations in fetal heart rate occurring during uterine contractions are associated with increased fetal death rate, growth retardation and neonatal depression. [1] [2] This test assesses fetal heart rate in response to uterine contractions via electronic fetal monitoring.
Today, a dedicated fetal echocardiogram can detect nearly 100% of serious congenital heart disease. Yet most pregnant women do not have a fetal echocardiogram but rather undergo a general obstetric ultrasound that may detect only around a third of fetal heart disease. To improve detection, some propose universal fetal echocardiography. [2]