enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    NFPA Clean Agent Retention testing (this type of testing is usually described as a door fan test rather than a blower door test) Duct leakage testing of forced air heating/cooling systems - both supply (vents) ducts and return ducts can be tested to determine if and how much they leak air. A duct test can be combined with a blower door test to ...

  3. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  4. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Smoke candles and blower-door tests can help identify less-than-obvious leaks. The Weatherization article describes methods for energy savings further. If infiltration is reduced below 0.35 ACH, it is recommended that mechanical ventilation (typically an exhaust fan or heat recovery ventilation ) be implemented.

  5. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    Building airtightness levels can be measured by using a fan, temporarily installed in the building envelope (a blower door) to pressurize the building. Air flow through the fan creates an internal, uniform, static pressure within the building.

  6. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    The most common technique to measure airtightness is the fan pressurization method, also known as the blower door test. It is measured by the number of air changes per hour (ACH) that occur when there is a differential pressure of 50 pascals between outside and inside the building.

  7. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  8. Are these prices a mistake? Someone forgot to turn off these ...

    www.aol.com/lifestyle/are-these-prices-a-mistake...

    Snag the carpet and upholstery cleaner than more than 10,000 Walmart reviewers already love, still on sale for the same price it was on Black Friday weekend.

  9. Air door - Wikipedia

    en.wikipedia.org/wiki/Air_door

    A typical commercial air curtain enclosure. In North America, the more commonly-used term for an air door is "air curtain". The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) defines an air door as follows: "In its simplest application, an air curtain is a continuous broad stream of air circulated across a doorway of a conditioned space.