enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Structural insulated panel - Wikipedia

    en.wikipedia.org/wiki/Structural_insulated_panel

    EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...

  3. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  4. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  5. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  6. Building insulation - Wikipedia

    en.wikipedia.org/wiki/Building_insulation

    The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.

  7. Rigid panel - Wikipedia

    en.wikipedia.org/wiki/Rigid_panel

    A multi-family residential building under construction with rigid panel exterior insulating sheathing. Rigid panel insulation, also referred to as continuous insulation, [1] can be made from foam plastics such as polyurethane (PUR), polyisocyanurate (PIR), and polystyrene, or from fibrous materials such as fiberglass, rock and slag wool.

  8. Sandwich panel - Wikipedia

    en.wikipedia.org/wiki/Sandwich_panel

    Sandwich panels have λ-values from 0.024 W/(m·K) for polyurethane to 0.05 W/(m·K) for mineral wool. Therefore, they can achieve different U-values depending on the core and the thickness of the panel. The installation of a system with sandwich panels minimizes thermal bridges through the joints.

  9. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    R-Value 3.4 – 3.8 (RSI-0.60 – 0.67) per inch (imperial units) Loose fill insulation fills the wall cavity better than batts. Wet-spray applications typically seal even better than dry-spray. Class I fire safety rating; No formaldehyde-based binders; Not made from petrochemicals nor chemicals with a high toxicity