enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fusion beat - Wikipedia

    en.wikipedia.org/wiki/Fusion_beat

    The arrow indicates a fusion beat on this ECG. A fusion beat occurs when electrical impulses from different sources act upon the same region of the heart at the same time. [1] If it acts upon the ventricular chambers it is called a ventricular fusion beat, whereas colliding currents in the atrial chambers produce atrial fusion beats.

  3. Parasystole - Wikipedia

    en.wikipedia.org/wiki/Parasystole

    fusion beats. According to the modulated parasystole hypothesis, rigid constancy of a pacemaker might be expected if the entrance block were complete, but if there is an escape route available for the emergence of ectopic activity, then clearly there must be an effective ionic communication, not complete insulation, between the two tissues.

  4. Rhythm interpretation - Wikipedia

    en.wikipedia.org/wiki/Rhythm_interpretation

    Rhythm interpretation is an important part of healthcare in Emergency Medical Services . Trained medical personnel can determine different treatment options based on the cardiac rhythm of a patient. There are many common heart rhythms that are part of a few different categories, sinus arrhythmia, atrial arrhythmia, ventricular arrhythmia.

  5. Junctional rhythm - Wikipedia

    en.wikipedia.org/wiki/Junctional_rhythm

    Accelerated junctional rhythm is when the rhythm of emerged impulses is more than 40 to 60 beats per minute, which is the natural range of the junction. It happens in some instances such as digoxin toxicity, and usually has a rate of between 60 and 100 bpm.

  6. Bigeminy - Wikipedia

    en.wikipedia.org/wiki/Bigeminy

    Bigeminy is a cardiac arrhythmia in which there is a single ectopic beat, or irregular heartbeat, following each regular heartbeat. Most often this is due to ectopic beats occurring so frequently that there is one after each sinus beat, or normal heartbeat. The two beats are figuratively similar to two twins (hence bi-+ gemini).

  7. Ventricular escape beat - Wikipedia

    en.wikipedia.org/wiki/Ventricular_escape_beat

    Ventricular escape beats occur when the rate of electrical discharge reaching the ventricles (normally initiated by the heart's sinoatrial node (SA node), transmitted to the atrioventricular node (AV node), and then further transmitted to the ventricles) falls below the base rate determined by the rate of Phase 4 spontaneous depolarisation of ventricular pacemaker cells. [1]

  8. Cannon A waves - Wikipedia

    en.wikipedia.org/wiki/Cannon_A_waves

    Cannon A wave. Cannon A waves, or cannon atrial waves, are waves seen occasionally in the jugular vein of humans with certain cardiac arrhythmias.When the atria and ventricles happen to contract simultaneously, the right atrium contracts against a closed tricuspid valve, resulting in back pressure into the venous system that can be seen in the jugular venous pulse as a high-amplitude "cannon ...

  9. Ectopic pacemaker - Wikipedia

    en.wikipedia.org/wiki/Ectopic_pacemaker

    Location of the pacemaker can also change its effect on the SA node and its rhythm. An ectopic pacemaker located in the atria is known as an atrial pacemaker and can cause the atrial contraction to be faster. [10] An ectopic pacemaker situated near the AV node and the septum is known as a junctional pacemaker. [11]