Carotid ultrasound is a low-cost, noninvasive, and accurate diagnostic imaging modality used to evaluate diseases of the carotid arteries. [2] It is most often used to diagnose carotid artery stenosis, a form of atherosclerosis , and has the capability to assess plaque morphology and characteristics. [ 1 ]
The carotid artery is the usual site of measurement of IMT and consensus statements for carotid IMT have been published for adults [12] and children. [13] Often, carotid IMT is measured in three locations: in the common carotid artery (typically at one cm proximal to the flow divider), at the bifurcation, and in the internal carotid artery.
The machine used is called an ultrasound machine, a sonograph or an echograph. The visual image formed using this technique is called an ultrasonogram, a sonogram or an echogram. Ultrasound of carotid artery. Ultrasound is composed of sound waves with frequencies greater than 20,000 Hz, which is the approximate upper threshold of human hearing. [1]
The surgical mortality of endarterectomy ranges from 1–2% to as much as 10%. Two large randomized clinical trials have demonstrated that carotid surgery done with a 30-day stroke and death risk of 3% or less will benefit asymptomatic people with ≥60% stenosis who are expected to live at least 5 years after surgery.
Carotid artery disease can be typically addressed with open surgical techniques (carotid endarterectomy) or though endovascular stenting. Chronic mesenteric ischemia can produce severe pain with eating and result in food fear and weight loss. These vascular disorders can be repaired by endovascular approaches using angioplasty and stenting.
Contrast injection rate is 6 to 7 ml/sec with total volume of contrast at 10 ml. [8] [9] The frame rate of fluoroscopy is 2 to 4 frames/sec. [8] Neck extension can help to navigate into tortous cerival part of the internal carotid artery. [14] [15] At the level of carotid bifurcation, AP and oblique images are taken.
There is no evidence to support the use of ultrasound for the treatment of low back pain, [24] and current clinical guidelines recommend that ultrasound is not used for this condition. [25] In a critical review, it was demonstrated that therapeutic ultrasound was effective in improving pain, function, and cartilage repair in knee osteoarthritis.
Stratosphere sign is a clinical medical ultrasound finding usually in an eFAST examination that can prove presence of a pneumothorax. The sign is an imaging finding using a 3.5–7.5 MHz ultrasound probe in the fourth and fifth intercostal spaces in the anterior clavicular line using the M-Mode of the machine. This finding is seen in the M-mode ...