enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. File:Ground loop solution - isolation transformer.svg - Wikipedia

    en.wikipedia.org/wiki/File:Ground_loop_solution...

    English: A schematic diagram showing one solution to the problem of a ground loop between electronic components - insert an isolation transformer in the signal cable. A ground loop is an inadvertent electrical circuit or loop created by the ground wiring of electrical equipment. Ground loops are a major cause of hum and interference in audio ...

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Isolation transformer Use a ground loop isolation transformer in the cable. [4] [5] This is considered the best solution, as it breaks the DC connection between components while passing the differential signal on the line. Even if one or both components are ungrounded, no noise will be introduced.

  4. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    In electronics testing and servicing, an isolation transformer is a 1:1 (under load) power transformer used for safety. Without it, exposed live metal in a device under test is at a hazardous voltage relative to grounded objects such as a heating radiator or oscilloscope ground lead (a particular hazard with some old vacuum-tube equipment with ...

  5. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    A 120:120 instrument isolation transformer showing two polarity marking conventions. Voltage transformers (VT), also called potential transformers (PT), are a parallel-connected type of instrument transformer. They are designed to present a negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to ...

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral. The third phase, the "high leg" of the system (also referred to as the "wild leg"), has 208 V to neutral and ...

  7. Galvanic isolation - Wikipedia

    en.wikipedia.org/wiki/Galvanic_isolation

    Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted. [ 1 ] [ 2 ] Energy or information can still be exchanged between the sections by other means, such as capacitive , inductive , radiative , optical , acoustic , or mechanical coupling.

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A planar transformer Exploded view: the spiral primary "winding" on one side of the PCB (the spiral secondary "winding" is on the other side of the PCB) Manufacturers either use flat copper sheets or etch spiral patterns on a printed circuit board to form the "windings" of a planar transformer, replacing the turns of wire used to make other ...

  9. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    Transformer: sometimes changed to "L" for inductor TUN: Tuner: U, IC: Integrated circuit (IC) shorter "U" (unit) is preferred instead of "IC" V: Vacuum tube: VR: Voltage regulator (voltage reference), or variable resistor (potentiometer / trimmer / rheostat) voltage regulators are often "U" for IC, pots and trimmers often "R" for resistor X