Search results
Results from the WOW.Com Content Network
There are three different methods for detection of water shortage: Pressure switch on suction manifold or float switch/electrode relay in the supply tank: Dry-running protection with pressure/level switch. Measurement of inlet pressure in the suction manifold by means of an analogue pressure transmitter: Dry-running protection with pressure ...
Uses of pneumatic pressure switches include: Switch a household well water pump automatically when water is drawn from the pressure tank. Switching off an electrically driven gas compressor when a set pressure is achieved in the reservoir; Switching off a gas compressor, whenever there is no feed in the suction stage. in-cell charge control in ...
Means of control for multiple fixed delivery volume, low cost low complexity pumps; to provide variable flow as required by small (say +/- 10 psi) pressure increase or decrease of a system. Means of control for pump unloading / recirculation against no pressure, without electric pressure switches.
In general well heads are five nominal ratings of wellheads: 2, 3, 5, 10 and 15 (×1000) psi working pressure. They have an operating temperature range of −50 to +250 degrees Fahrenheit. They are used in conjunction with ring type seal gaskets.
The pressure switch turns the water pump on when it senses a pressure that is less than P lo and turns it off when it senses a pressure greater than P hi. While the pump is on, the pressure tank fills up. The pressure tank is then depleted as it supplies water in the specified pressure range to prevent "short-cycling", in which the pump tries ...
A safety valve allows water to escape from the system when pressure becomes too high, and a valve can open to replenish water from the normal water supply if the pressure drops too low. Sealed systems offer an alternative to open-vent systems, in which steam can escape from the system, and gets replaced from the building's water supply via a ...
Large industrial pumps may also serve as the feedwater pump for returning the condensate under pressure to a boiler. Condensate pumps usually run intermittently and have a tank in which condensate can accumulate. Eventually, the accumulating liquid raises a float switch energizing the pump. The pump then runs until the level of liquid in the ...
A pumpjack is the overground drive for a reciprocating piston pump in an oil well. [1] It is used to mechanically lift liquid out of the well if there is not enough bottom hole pressure for the liquid to flow all the way to the surface. The arrangement is often used for onshore wells. Pumpjacks are common in oil-rich areas.