enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cardiac magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Cardiac_magnetic_resonance...

    Some centers allow children to listen to music or watch movies through a specialized MRI-compatible audiovisual system to reduce anxiety and improve cooperation. However, the presence of a calm, encouraging, supportive parent generally produces better results in terms of pediatric cooperation than any distraction or entertainment strategy short ...

  3. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    Inversion recovery Short tau inversion recovery: STIR: Fat suppression by setting an inversion time where the signal of fat is zero. [10] High signal in edema, such as in more severe stress fracture. [11] Shin splints pictured: Fluid-attenuated inversion recovery: FLAIR: Fluid suppression by setting an inversion time that nulls fluids

  4. Safety of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Safety_of_magnetic...

    All patients are reviewed for contraindications prior to MRI scanning. Medical devices and implants are categorized as MR Safe, MR Conditional or MR Unsafe: [6] MR-Safe – The device or implant is completely non-magnetic, non-electrically conductive, and non-RF reactive, eliminating all of the primary potential threats during an MRI procedure.

  5. MRI pulse sequence - Wikipedia

    en.wikipedia.org/wiki/MRI_pulse_sequence

    An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .

  6. Pacemaker failure - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_failure

    The magnet can interrupt the pacing and inhibit the output of pacemakers. If MRI must be done, the pacemaker output in some models can be reprogrammed. [7] In February 2011, the FDA approved an MRI-safe pacemaker. [8] Extracorporeal shock-wave lithotripsy (ESWL) procedure is safe for most pacemaker patients, with some reprogramming of the pacing.

  7. Inversion recovery - Wikipedia

    en.wikipedia.org/wiki/Inversion_recovery

    Inversion recovery is a magnetic resonance imaging sequence that provides high contrast between tissue and lesion. It can be used to provide high T1 weighted image, high T2 weighted image, and to suppress the signals from fat , blood , or cerebrospinal fluid (CSF).

  8. Pacemaker syndrome - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_syndrome

    [17] [18] [19] The name pacemaker syndrome was first coined by Erbel in 1979. [18] [20] Since its first discovery, there have been many definitions of pacemaker syndrome, and the understanding of the cause of pacemaker syndrome is still under investigation. In a general sense, pacemaker syndrome can be defined as the symptoms associated with ...

  9. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    Modern 3 Tesla clinical MRI scanner.. Magnetic resonance imaging (MRI) is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels ...