enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Boiler water - Wikipedia

    en.wikipedia.org/wiki/Boiler_water

    Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater , steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

  3. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...

  4. Steam and water analysis system - Wikipedia

    en.wikipedia.org/wiki/Steam_and_water_analysis...

    Steam and water analysis system (SWAS) [1] is a system dedicated to the analysis of steam or water.In power stations, it is usually used to analyze boiler steam and water to ensure the water used to generate electricity is clean from impurities which can cause corrosion to any metallic surface, such as in boiler and turbine.

  5. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    For this, continuous make-up water is added to the boiler water system. Impurities in the raw water input to the plant generally consist of calcium and magnesium salts which impart hardness to the water. Hardness in the make-up water to the boiler will form deposits on the tube water surfaces which will lead to overheating and failure of the tubes.

  6. Cogeneration - Wikipedia

    en.wikipedia.org/wiki/Cogeneration

    Because boiler feed water from cogeneration plants has much lower return rates than 100% condensing power plants, industries usually have to treat proportionately more boiler make up water. Boiler feed water must be completely oxygen free and de-mineralized, and the higher the pressure the more critical the level of purity of the feed water. [5]

  7. Dealkalization of water - Wikipedia

    en.wikipedia.org/wiki/Dealkalization_of_water

    In general, a dealkalizer is best applied to boilers operating below 700 psi (48 bar). In order to justify installation of a dealkalizer on low-pressure boilers, the alkalinity content should be above 50 ppm with the amount of make-up water exceeding 1,000 gallons (approx. 4,000 litres) per day.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Boiler blowdown - Wikipedia

    en.wikipedia.org/wiki/Boiler_blowdown

    These water treatments often include compounds forming a sludge to entrap such particles; and boilers intended for such water treatment include a structure called a mud drum at the lowest part of the boiler. Bottom blowdown involves periodically opening valves in the mud drum to allow boiler pressure to force accumulated sludge out of the boiler.