Additionally, the shape of the PPG waveform differs from subject to subject, and varies with the location and manner in which the pulse oximeter is attached. Although PPG sensors are in common use in a number of commercial and clinical applications, the exact mechanisms determining the shape of the PPG waveform are not yet fully understood. [6]
A pulse oximeter probe applied to a person's finger. A pulse oximeter is a medical device that indirectly monitors the oxygen saturation of a patient's blood (as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in the skin, producing a photoplethysmogram that may be further processed into other measurements. [4]
Wiggers with jugular venous waveform Wiggers diagram with mechanical (echo), electrical (ECG), and aortic pressure (catheter) waveforms, together with an in-ear dynamic pressure waveform measured using a novel infrasonic hemodynography technology, for a patient with severe aortic stenosis.
Example pulse oximeter. Pulse oximetry is a method used to estimate the percentage of oxygen bound to hemoglobin in the blood. [10] This approximation to SaO 2 is designated SpO 2 (peripheral oxygen saturation). The pulse oximeter is a small device that clips to the body (typically a finger, an earlobe or an infant's foot) and displays its ...
Finger tip carboxyhemoglobin saturation monitor.. A CO-oximeter is a device that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) (formerly, but incorrectly, referred to as 'reduced' hemoglobin), as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb).
The functional oxygen saturation measured by this procedure is the basis for calibrating pulse oximeters. Pulse oximeters cannot be calibrated using physical procedures, but only by directly comparing the reported measurements and the parallel arterial oxygen saturation measured by hemoximetry in a group of healthy subjects. [citation needed]
A pulse wave or pulse train or rectangular wave is a non-sinusoidal waveform that is the periodic version of the rectangular function. It is held high a percent each cycle called the duty cycle and for the remainder of each cycle is low. A duty cycle of 50% produces a square wave, a specific case of a rectangular wave. The average level of a ...
This short sharp change in pressure is rapidly attenuated down the arterial tree. The pulse wave form is also reflected from branches in the arterial tree and gives rise to a dicrotic notch in main arteries. The summation of the reflected pulse wave and the systolic wave may increase pulse pressure and help tissue perfusion.