Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...
Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as
Whether the analyte is reduced or oxidized depends on the analyte and the potential applied, but its reaction always occurs at the working/indicator electrode. Therefore, the working electrode potential varies as a function of the analyte concentration. A second auxiliary electrode completes the electric circuit, called the counter electrode.
Most electrodes work over a limited range of conditions, such as pH or temperature, outside of this range the electrodes behavior becomes unpredictable. The advantage of a pseudo-reference electrode is that the resulting variation is factored into the system allowing researchers to accurately study systems over a wide range of conditions.
The counter electrode, also known as the auxiliary or second electrode, can be any material that conducts current easily, will not react with the bulk solution, and has a surface area much larger than the working electrode. Common choices are platinum and graphite. Reactions occurring at the counter electrode surface are unimportant as long as ...
A redox indicator (also called an oxidation-reduction indicator) is an indicator which undergoes a definite color change at a specific electrode potential. The requirement for fast and reversible color change means that the oxidation-reduction equilibrium for an indicator redox system needs to be established very quickly. Therefore, only a few ...
1/2 cup water. 1/2 cup honey. 1 sprig rosemary. 2 pears pureed. Champagne or prosecco. Directions. Start by bringing water and honey to a boil. Remove from heat and add rosemary sprig.
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .