enow.com Web Search

  1. Ad

    related to: back drag for hla 1500 watt transformer installation manual

Search results

  1. Results from the WOW.Com Content Network
  2. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    At each transformer, such as a customer's premises, current flows from the line, through the primary coil of a step-down isolation transformer, to earth through an earth stake. From the earth stake, the current eventually finds its way back to the main step-up transformer at the head of the line, completing the circuit . [ 3 ]

  3. Grounding transformer - Wikipedia

    en.wikipedia.org/wiki/Grounding_transformer

    A grounding transformer. A grounding transformer or earthing transformer is a type of auxiliary transformer used in three-phase electric power systems to provide a ground path to either an ungrounded wye or a delta-connected system. [1] [2] Grounding transformers are part of an earthing system of the network.

  4. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  6. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    Single- and three-phase pad-mounted transformers are used in underground industrial and residential power distribution systems, where there is a need for safe, reliable, and aesthetically appealing transformer design. Their enclosed construction allows the installation of pad-mount transformers in public areas without protective fencing.

  7. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...

  8. “The Voice” Alum Ryan Whyte Maloney Dies at 44 - AOL

    www.aol.com/lifestyle/voice-alum-ryan-whyte...

    In 2014, Whyte Maloney appeared on The Voice, where he performed "Lights" by Journey in a blind audition and received a four-chair turn.. Whyte Maloney joined Blake Shelton's team where he endured ...

  9. Backfeeding - Wikipedia

    en.wikipedia.org/wiki/Backfeeding

    A common source of unintentional backfeeding is an electrical generator (typically a portable generator) that is improperly connected to a building electrical system.A properly installed electrical generator incorporates the use of a transfer switch or generator interlock kit to ensure the incoming electrical service line is disconnected when the generator is providing power to the building.

  1. Ad

    related to: back drag for hla 1500 watt transformer installation manual