enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fixation disparity - Wikipedia

    en.wikipedia.org/wiki/Fixation_disparity

    A fixation disparity is not constant within a certain observer, but can vary depending on the viewing conditions. If test prisms with increasing amount are placed in front of the observer’s eyes, the fixation disparity changes in the eso direction with base-in prisms and in the exo direction with base-out prisms (Fig. 3).

  3. Exophoria - Wikipedia

    en.wikipedia.org/wiki/Exophoria

    Exophoria. Exophoria is a form of heterophoria in which there is a tendency of the eyes to deviate outward. [1] During examination, when the eyes are dissociated, the visual axes will appear to diverge away from one another. [2] The axis deviation in exophoria is usually mild compared with that of exotropia.

  4. Prism fusion range - Wikipedia

    en.wikipedia.org/wiki/Prism_fusion_range

    The prism fusion range (PFR) or fusional vergence amplitude is a clinical eye test performed by orthoptists, optometrists, and ophthalmologists to assess motor fusion, specifically the extent to which a patient can maintain binocular single vision (BSV) in the presence of increasing vergence demands. Motor fusion is largely accounted to ...

  5. Vergence - Wikipedia

    en.wikipedia.org/wiki/Vergence

    The two eyes converge to point to the same object. A vergence is the simultaneous movement of both eyes in opposite directions to obtain or maintain single binocular vision. [1] When a creature with binocular vision looks at an object, the eyes must rotate around a vertical axis so that the projection of the image is in the centre of the retina ...

  6. Dissociated vertical deviation - Wikipedia

    en.wikipedia.org/wiki/Dissociated_vertical_deviation

    DVD can be revealed on ocular movement testing when one eye is occluded by the nose on lateral gaze. This eye will then elevate, simulating an inferior oblique over action. However, in a unilateral case, overaction of the superior rectus muscle in the unaffected dominant eye, can also be a causing factor as well as causing a V pattern exophoria.

  7. Worth 4 dot test - Wikipedia

    en.wikipedia.org/wiki/Worth_4_dot_test

    Worth 4 dot test. The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a single image.

  8. Accommodative convergence - Wikipedia

    en.wikipedia.org/wiki/Accommodative_convergence

    Accommodative convergence is that portion of the range of inward rotation of both eyes (i.e., convergence) that occurs in response to an increase in optical power for focusing by the crystalline lens (i.e., accommodation). [1] When the human eye engages the accommodation system to focus on a near object, signal is automatically sent to the ...

  9. Maddox wing - Wikipedia

    en.wikipedia.org/wiki/Maddox_Wing

    Maddox wing. The Maddox Wing is an instrument utilized by ophthalmologists, orthoptists and optometrists in the measurement of strabismus (misalignment of the eyes; commonly referred to as a squint or lazy eye by the lay person). It is a quantitative and subjective method of measuring the size of a strabismic deviation by dissociation of the ...