In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...
In electrical engineering, IEC 60269 is a set of technical standards for low-voltage power fuses. [1] The standard is in four volumes, which describe general requirements, fuses for industrial and commercial applications, fuses for residential applications, and fuses to protect semiconductor devices.
cut out), the sealed box containing the main supply fuse. This fuse will typically be rated either 60, 80 or 100 amps. Separate line and neutral cables (tails) go from here to an electricity meter. More tails proceed from the meter into a consumer unit (or fusebox in older installations), possibly via an isolator. Some installations may have ...
[53] The original BS 1363:1947 specified fuse ratings of 3 A, 7 A and 13 A. [54] The current version of the fuse standard, BS 1362:1973, allows any fuse rating up to 13 A, with 3 A (coloured red) and 13 A (coloured brown) as the preferred (but not mandated) values when used in a plug. All other ratings are to be coloured black.
Compared to modern electrical wiring standards, these are the main technical shortcomings of knob-and-tube wiring methods: never included a safety grounding conductor; did not confine switching to the hot conductor (the so-called Carter system prohibited as of 1923 places electrical loads across the common terminals of a three-way switch pair)
Automotive fuses are used to protect the wiring and electrical equipment for vehicles. There are several different types of automotive fuses and their usage is dependent upon the specific application, voltage, and current demands of the electrical circuit. Automotive fuses can be mounted in fuse blocks, inline fuse holders, or fuse clips.
On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...
electrical equipment of machines covered by BS EN 60204 electric fences covered by BS EN 60335-2-76 the DC side of cathodic protection systems complying with the relevant part(s) of BS EN ISO 12696, BS EN 12954, BS EN ISO 13174, BS EN 13636 and BS EN 14505.