FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket."
The taper rate for all NPT threads is 1 inch of diameter in 16 inches of length (3 ⁄ 4 inch per foot or 62.5 millimeters per meter) measured by the change of diameter (of the pipe thread) over distance of thread. The half-angle (between the taper surface and the axis of the pipe) is arctan(1 ⁄ 32) ≈ 1.7899° ≈ 1° 47′.
[1] AN sizes range from -2 (dash two) to -32 in irregular steps, with each step equating to the OD (outside diameter) of the tubing in 1 ⁄ 16-inch increments. Therefore, a -8 AN size would be equal to 1 ⁄ 2-inch OD tube. However, this system does not specify the ID (inside diameter) of the tubing because the tube wall can vary in thickness.
Common sizes are 15 mm and 22 mm. [7] Other sizes include 18 mm, 28 mm, 35 mm, 42 mm, 54 mm, 66.7 mm, 76.1 mm, and 108 mm outside diameters. Tubing in 8 mm and 10 mm outside diameters is called a "micro bore" and is easier to install, although there is a slightly increased risk of blockage from scale or debris.
The only way to obtain the actual OD is to look it up in a reference table. For pipe sizes of NPS 14 inch (DN 350) and greater the NPS size is the actual diameter in inches and the DN size is equal to NPS times 25 (not 25.4) rounded to a convenient multiple of 50. For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The variations of Q/Q (full) and V/V (full) with H/D ratio is shown in figure(b).From the equation 5, maximum value of Q/Q (full) is found to be equal to 1.08 at H/D =0.94 which implies that maximum rate of discharge through a conduit is observed for a conduit partly full.
Power cables use stranded copper or aluminum conductors, although small power cables may use solid conductors in sizes of up to 1/0. (For a detailed discussion on copper cables, see: Copper wire and cable.). The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection.
Ads
related to: 1 rigid conduit dimensions chart feet and meters widthzoro.com has been visited by 1M+ users in the past month