Mechanically seamed metal with concealed fasteners contains sealant in seams for use on very low sloped roofs, suitable for roofs of low pitch such as 0.5/12 to 3/12 pitch. Flat-seam metal with or without soldered seams. Steel coated with a coloured alloy of zinc and aluminium. Stone-coated metal roofing.
A flat roof includes pitches as low as 1 ⁄ 2:12 to 2:12 (1 in 24 to 1 in 6), which are barely capable of properly shedding water. Such low-slope roofs (up to 4:12 (1 in 3)) require special materials and techniques to avoid leaks. [4] Conventional describes pitches from 4:12 (1 in 3) to 9:12 (3 in 4). [4]
Flat roofs, or "low-slope" roofs, are also commonly found on commercial buildings throughout the world. The U.S.-based National Roofing Contractors Association defines a low-slope roof as having a slope of 3 in 12 (1:4) or less. [2] Flat roofs exist all over the world, and each area has its own tradition or preference for materials used.
Satari: A Swedish variant on the monitor roof; a double hip roof with a short vertical wall usually with small windows, popular from the 17th century on formal buildings. [citation needed] (Säteritak in Swedish.) Mansard (French roof): A roof with the pitch divided into a shallow slope above a steeper slope. The steep slope may be curved.
The purlins are the large beams perpendicular to the rafters; from this shot, it appears that there are three purlins on either side of the roof. The sheathing boards are sometimes called the roof deck and are painted white. A purlin (or historically purline, purloyne, purling, perling) is a longitudinal, horizontal, structural member in a roof.
Eaves must be designed for local wind speeds as the overhang can significantly increase the wind loading on the roof. [7] The line on the ground under the outer edge of the eaves is the eavesdrip, or dripline, and in typical building planning regulations defines the extent of the building and cannot oversail the property boundary.
A hot roof is a roof designed not to have any ventilation and has enough air-impermeable insulation in contact with the sheathing to prevent condensation [11] such as when spray foam insulation is applied directly to the under-side or top-side of the roof deck or in some cathedral ceilings. [12]
The difference can be illustrated by the fact that an insulated attic floor is the primary thermal control layer between the inside of the house and the exterior while the entire roof (from the surface of the roofing material to the interior paint finish on the ceiling) is part of the building envelope.