enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reference electrode - Wikipedia

    en.wikipedia.org/wiki/Reference_electrode

    To focus on the reaction at the working electrode, the reference electrode is standardized with constant (buffered or saturated) concentrations of each participant of the redox reaction. [1] There are many ways reference electrodes are used. The simplest is when the reference electrode is used as a half-cell to build an electrochemical cell.

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [5] using electrodes placed on the skin.

  4. Silver chloride electrode - Wikipedia

    en.wikipedia.org/wiki/Silver_chloride_electrode

    Commercial reference electrodes consist of a glass or plastic tube electrode body. The electrode consists of a metallic silver wire (Ag (s)) coated with a thin layer of silver chloride (AgCl), either physically by dipping the wire in molten silver chloride, chemically by electroplating the wire in concentrated hydrochloric acid (HCl) [3] or electrochemically by oxidising the silver at an anode ...

  5. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Electrodes may be placed distally or proximally on the limb without affecting the recording. [5] The right leg electrode acts to reduce interference, and can be placed anywhere without an effect on the ECG results. [6] Each lead measures the electric field created by the heart during the depolarization and repolarization of myocytes. The ...

  6. Driven right leg circuit - Wikipedia

    en.wikipedia.org/wiki/Driven_right_leg_circuit

    Driven Right Leg Circuit for Electrocardiogram. A Driven Right Leg circuit or DRL circuit, also known as Right Leg Driving technique, is an electric circuit that is often added to biological signal amplifiers to reduce common-mode interference.

  7. Lewis lead - Wikipedia

    en.wikipedia.org/wiki/Lewis_lead

    A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG. In order to create the Lewis Lead, the right arm electrode is moved to the manubrium adjacent to the sternum ...

  8. 10–20 system (EEG) - Wikipedia

    en.wikipedia.org/wiki/10–20_system_(EEG)

    EKG artifact can be reduced with post-filtering of signals, or by "jumping" (co-referencing) of A/M reference electrodes, if replacement of reference electrodes is not possible, ameliorative, or if other clinical considerations prevent otherwise good placement (such as congenital malformation, or post-surgical considerations such as Cochlear ...

  9. Electrogram - Wikipedia

    en.wikipedia.org/wiki/Electrogram

    The typical meaning of an "ECG" is the 12-lead ECG that uses 10 wires or electrodes to record the signal across the chest. Interpretation of an ECG is the basis of a number of cardiac diseases including myocardial infarction (heart attack) and arrhythmias such as atrial fibrillation .