enow.com Web Search

  1. Ads

    related to: circuit breaker always trips for two phase
  2. ebay.com has been visited by 1M+ users in the past month

    • Home & Garden

      From Generators to Rugs to Bedding.

      You’ll Find Everything You Need

    • Gift Cards

      eBay Gift Cards to the Rescue.

      Give The Gift You Know They’ll Love

    • Electronics

      From Game Consoles to Smartphones.

      Shop Cutting-Edge Electronics Today

    • Daily Deals

      Lowest Prices on Top Items.

      Save Money with eBay Deals.

Search results

  1. Results from the WOW.Com Content Network
  2. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Three-pole common-trip breaker for supplying a three-phase device. This breaker has a 2 A rating. To provide simultaneous breaking on multiple circuits from a fault on any one, circuit breakers may be made as a ganged assembly.

  3. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only ...

  4. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  5. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current. That is why we calculate 130 V × √ 3 = 225 V.

  6. Electric power system - Wikipedia

    en.wikipedia.org/wiki/Electric_power_system

    Some miniature circuit breakers operate solely on the basis of electromagnetism. In these miniature circuit breakers, the current is run through a solenoid, and, in the event of excess current flow, the magnetic pull of the solenoid is sufficient to force open the circuit breaker's contacts (often indirectly through a tripping mechanism).

  7. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A circuit breaker is used as a protection device to interrupt fault currents automatically, and may be used to switch loads on and off, or to cut off a line when power is flowing in the 'wrong' direction. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers. The magnitude of the ...

  8. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance. If this imbalance exceeds a pre-determined value, a circuit breaker should operate. Restricted earth fault protection is a type of earth fault protection which looks for earth fault between two sets of ...

  9. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).

  1. Ads

    related to: circuit breaker always trips for two phase