Search results
Results from the WOW.Com Content Network
This is the most common method of a contingency well kill. If there is a sudden need to kill a well quickly, without the time for rigging up for circulation, the more blunt instrument of bullheading may be used. This involves simply pumping the kill fluid directly down the well bore, forcing the well bore fluids back into the reservoir. This ...
Gas lift well: gas is fed into valves installed in mandrels in the tubing strip. The hydrostatic head is lowered and the fluid is gas lifted to the surface. Single-well alternate completions: in this instance there is a well with two zones. In order to produce from both the zones are isolated with packers.
Well control is the technique used in oil and gas operations such as drilling, well workover and well completion for maintaining the hydrostatic pressure and formation pressure to prevent the influx of formation fluids into the wellbore.
“Kill” the well (prevent the flow of formation fluid, influx, from the reservoir into the wellbore); Seal the wellhead (close off the wellbore); Sever the casing or drill pipe (in case of emergencies). In drilling a typical high-pressure well, drill strings are routed through a blowout preventer stack toward the reservoir of oil and gas
After lengthy preparations, BP (BP) and the government will begin a series of "injection tests" Monday evening to determine whether the damaged Deepwater Horizon oil well in the Gulf of Mexico is ...
Source: [42] A well kill procedure is an oil well control method. Once the well has been shut-in on a kick , proper kill procedures must be done immediately. The general idea in well kill procedure is to circulate out any formation fluid already in the wellbore during kick, and then circulate a satisfactory weight of kill mud called Kill Weight ...
A well control company then will need to extinguish the well fire or cap the well, and replace the casing head and other surface equipment. If the flowing gas contains poisonous hydrogen sulfide , the oil operator might decide to ignite the stream to convert this to less hazardous substances.
Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.