enow.com Web Search

  1. Ads

    related to: 20a double pole breaker

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    In the US, where split-phase supplies are common, in a branch circuit with more than one live conductor, each live conductor must be protected by a breaker pole. To ensure that all live conductors are interrupted when any pole trips, a common-trip set of breakers must be used. These may either contain two or three tripping mechanisms within one ...

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Even when unmarked, it is generally easy to identify this type of system, because the B phase (circuits #3 and #4) and every third circuit afterwards will be either a three-pole breaker or a blank. Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V ...

  6. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    A pole will be either a neutral [12] connection or a line [13] Neutral is usually very near to earth potential, usually being earthed either at the distribution board or at the substation. Line (also known as phase or hot , and commonly, but technically incorrectly, as live ) carries the full supply voltage relative to the neutral (and to earth).

  7. Switch - Wikipedia

    en.wikipedia.org/wiki/Switch

    Single pole, double throw: Two-way: Three-way: A simple break-before-make changeover switch: C (COM, Common) is connected either to L1 or to L2. SPCO SPTT, c.o. Single pole changeover or single pole, centre off or single pole, triple throw Similar to SPDT.

  1. Ads

    related to: 20a double pole breaker