  2. AS/NZS 3112 - Wikipedia

    en.wikipedia.org/wiki/AS/NZS_3112

    The pins are arranged at 120° angles around a common midpoint, with the active and neutral centred 7.92 mm (5 ⁄ 16 in) from the midpoint, and the earth pin centred 10.31 mm (3 ⁄ 8 in) away. [15] A standard socket-outlet provides a nominal RMS voltage of 230 volts [2] at a maximum of 10 amps and always includes an earth connection ...

  3. AC power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets

    Chinese dual sockets have both an unearthed socket complying with figure 5 of GB 1002-2008 (both flat pin and 4.8 mm round pin), and an earthed socket complying with figure 4 of GB 1002-2008. The latter was removed from the 2021 revision of the Chinese standard, [ 7 ] but such dual sockets can still be found in many existing installations.

  4. AC power plugs and sockets: British and related types

    en.wikipedia.org/wiki/AC_power_plugs_and_sockets:...

    BS 546, Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50–60 Hz) circuits up to 250 V is an older British Standard for three-pin AC power plugs and sockets: four sizes with current capacities from 2 A to 30 A. Originally published in April 1934, it was updated by a 1950 edition which is still current, [1 ...

  5. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The yellow P+N+E, 4h (120°) plug is a single phase connector that is in widespread use on the British Isles for 110 V building site and fairground applications. A popular model of this socket type is marketed under the brand name MK Commando [12] which leads some users to refer to all IEC 60309 sockets by the generic trademark Commando sockets.

  6. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The addition is a 3 ⁄ 16-inch (4.8 mm) diameter round or U-shaped ground pin, 1 ⁄ 8 in (3.2 mm) longer than the power blades (so the device is grounded before the power is connected) and located from them by 1 ⁄ 4 in (6.4 mm) edge-to-edge or 15 ⁄ 32 in (11.9 mm) center-to-center.

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  9. IEC 60320 - Wikipedia

    en.wikipedia.org/wiki/IEC_60320

    A variety of different kinds of IEC 60320 plugs and sockets. IEC 60320 Appliance couplers for household and similar general purposes [1] is a set of standards from the International Electrotechnical Commission (IEC) specifying non-locking connectors for connecting power supply cords to electrical appliances of voltage not exceeding 250 V (a.c.) and rated current not exceeding 16 A. [1 ...