  2. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    In a variable primary chilled-water system, the design flow rate is determined by the water flow velocity in the tube of the coils. At typical conditions, 6–7 feet per second (1.8–2.1 m/s) Maximum 12 ft/s (3.7 m/s) Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1]

  3. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    A chiller used to create chilled water as part of a chilled water system. Chilled water is a commodity often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. The chilled water can be supplied by a vendor, such as a public utility, or created at the ...

  4. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Drift (or windage) is the term for water droplets of the process flow allowed to escape in the cooling tower discharge. Drift eliminators are used in order to hold drift rates typically to 0.001–0.005% of the circulating flow rate. A typical drift eliminator provides multiple directional changes of airflow to prevent the escape of water droplets.

  5. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    Q is the rate of flow (expressed in US gallons per minute), SG is the specific gravity of the fluid (for water = 1), ΔP is the pressure drop across the valve (expressed in psi). In more practical terms, the flow coefficient C v is the volume (in US gallons) of water at 60 °F (16 °C) that will flow per minute through a valve with a pressure ...

  6. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  7. District cooling - Wikipedia

    en.wikipedia.org/wiki/District_cooling

    A second district cooling plant was commissioned in May 2010, [17] which will supply chilled water for the air-conditioning of buildings in the area through pipes housed within the Common Services Tunnel in Marina Bay. The second district cooling plant started operations on 3 March 2016.

  8. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs ...

  9. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    In most contexts a mention of rate of fluid flow is likely to refer to the volumetric rate. In hydrometry, the volumetric flow rate is known as discharge. Volumetric flow rate should not be confused with volumetric flux, as defined by Darcy's law and represented by the symbol q, with units of m 3 /(m 2 ·s), that is, m·s −1. The integration ...