Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others. Nameplate capacity is the ...
Full Load hour is a measure of the degree of utilisation of a technical system. [1] [2] [3] Full load hours refer to the time for which a plant would have to be operated at nominal power in order to convert the same amount of electrical work as the plant has actually converted within a defined period of time, during which breaks in operation or partial load operation can also occur.
The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added).
If a plant is only needed during the day, for example, even if it operates at full power output from 8 am to 8 pm every day (12 hours) all year long, it would only have a 50% capacity factor. Due to low capacity factors, electricity from peaking power plants is relatively expensive because the limited generation has to cover the plant fixed costs.
In 2021, the worldwide installed capacity of power plants increased by 347 GW. Solar and wind power plant capacities rose by 80% in one year. [27] As of 2022, the largest photovoltaic (PV) power plants in the world are led by Bhadla Solar Park in India, rated at 2245 MW. Solar thermal power stations in the U.S. have the following output:
The capacity factor of a plant includes numerous other factors which determine the durations the plant is planned to produce electricity. A solar photovoltaic plant is not planned to operate in the dark of a night, hence unplanned maintenance occurring whilst the sun is set does not impact the availability factor.
As of 2019, about 97% of utility-scale solar power capacity was PV. [1] [2] In some countries, the nameplate capacity of photovoltaic power stations is rated in megawatt-peak (MW p), which refers to the solar array's theoretical maximum DC power output. In other countries, the manufacturer states the surface and the efficiency.
The motor load factor is then 12/15 = 80%. The motor above may only be used for eight hours a day, 50 weeks a year. The hours of operation would then be 2800 hours, and the motor use factor for a base of 8760 hours per year would be 2800/8760 = 31.96%. With a base of 2800 hours per year, the motor use factor would be 100%.