Search results
Results from the WOW.Com Content Network
Backflow occurs for one of two reasons, either back pressure or back siphonage. [1] Back pressure is the result of a higher pressure in the system than in its supply, i.e. the system pressure has been increased by some means. This may occur in unvented heating systems, where thermal expansion increases the pressure.
A significant drop of pressure in a water delivery system creates a similar suction, pulling possibly undesirable material into the system. This is an example of an indirect cross-connection . Back-pressure occurs for example when air is blown through the straw and bubbles begin to erupt at the submerged end.
Trap with copper drain pipe at underside of firestop packing in two-hour fire-resistance rated concrete floor slab Typical P-trap. Maintaining the water seal is critical to trap operation; traps might dry out, and poor venting can suction or blow water out of the traps. This is usually avoided by venting the drain pipes downstream of the trap ...
In the base cabinet under the sink, the drain hose from the dishwasher feeds the "top" of the air gap, and the "bottom" of the air gap is plumbed into the sink drain below the basket, or into a garbage disposal unit. When installed and maintained properly, the air gap works as described above, and prevents drain water from the sink from backing ...
A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, [1] [2] reduced pressure zone assemblies (RPZA), [3] or reduced pressure principle ...
Should the pressure within the water supply system fall, the external water may be returned by back pressure into the drinking water system through the faucet. Another possible contamination point is the water intake in the toilet tank. An anti-siphon valve is also required here to prevent pressure drops in the water supply line from suctioning ...
The drastic measure came after an issue with the flooring, which is uneven in every unit above the first floor and, in some cases, even sinks under the weight of normal couches and other furniture.
If the moving water is suddenly stopped, such as by closing a valve downstream of the flowing water, the pressure can rise suddenly with a resulting shock wave. In domestic plumbing this shock wave is experienced as a loud banging resembling a hammering noise. Water hammer can cause pipelines to break if the pressure is sufficiently high.