enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    NEMA connectors implement these requirements. The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces

  3. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    A receptacle with a green dot is a so-called "hospital grade" device; The primary reason to use a hospital-grade receptacle at a patient bed location is to ensure that a receptacle with a greater contact tension is provided to minimize possibilities that an attachment plug supplying medical or life support equipment may be disconnected because ...

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Terminals for the neutral (grounded) conductor in general, and for receptacles, plugs, and connectors specifically, are required to be substantially white in color [NEC 200.9, NEC 200.10 (B)], and if the terminal itself is not visible, the hole leading to it must be marked with the word "white" or the letter "W".

  5. IEC 60320 - Wikipedia

    en.wikipedia.org/wiki/IEC_60320

    A variety of different kinds of IEC 60320 plugs and sockets. IEC 60320 Appliance couplers for household and similar general purposes [1] is a set of standards from the International Electrotechnical Commission (IEC) specifying non-locking connectors for connecting power supply cords to electrical appliances of voltage not exceeding 250 V (a.c.) and rated current not exceeding 16 A. [1 ...

  6. Electrical connector - Wikipedia

    en.wikipedia.org/wiki/Electrical_connector

    The M12 connector, specified in IEC 61076-2-101, is a circular electrical plug/receptacle pair with 12mm OD mating threads, used in NMEA 2000, DeviceNet, IO-Link, some kinds of Industrial Ethernet, etc. [16] [17] A disadvantage of the circular design is its inefficient use of panel space when used in arrays, when compared to rectangular connectors.

  7. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    IP67 plug and receptacle. IEC 60309-2 connectors come in IP44 (splash-proof), IP67 (waterproof) and IP66/IP67 (jet-proof/waterproof) variants. In all cases, the rating applies when detached or mated, but not during the mating process. The more common IP44 variant features a spring-loaded hinged cap over the socket.

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  9. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    An electrical code is a term for a set of regulations for the design and installation of electrical wiring in a building. The intention of such regulations is to provide standards to ensure electrical wiring systems are safe for people and property, protecting them from electrical shock and fire hazards.