Search results

  1. Results from the WOW.Com Content Network
  2. Quality management system - Wikipedia

    en.wikipedia.org/wiki/Quality_management_system

    The two primary, state of the art, guidelines for medical device manufacturer QMS and related services today are the ISO 13485 standards and the US FDA 21 CFR 820 regulations. The two have a great deal of similarity, and many manufacturers adopt QMS that is compliant with both guidelines.

  3. Design controls - Wikipedia

    en.wikipedia.org/wiki/Design_controls

    Design history file, a demonstration that the design was developed according to the approved design plan and 21 CFR 820.30. The Medical Devices Directive (MDD 93/42/EEC) similarly lists several requirements regarding the design of a medical device.

  4. Verification and validation - Wikipedia

    en.wikipedia.org/wiki/Verification_and_validation

    Verification is intended to check that a product, service, or system meets a set of design specifications. [6] [7] In the development phase, verification procedures involve performing special tests to model or simulate a portion, or the entirety, of a product, service, or system, then performing a review or analysis of the modeling results.

  5. Title 21 of the Code of Federal Regulations - Wikipedia

    en.wikipedia.org/wiki/Title_21_of_the_Code_of...

    The 200 and 300 series are regulations pertaining to pharmaceuticals : 202-203 Drug advertising and marketing; 210 et seq. cGMPs for pharmaceuticals; 310 et seq. Requirements for new drugs; 328 et seq. Specific requirements for over-the-counter (OTC) drugs. The 500 series are regulations for animal feeds and animal medications: 510 et seq. New ...

  6. ISO 13485 - Wikipedia

    en.wikipedia.org/wiki/ISO_13485

    ISO 13485 Medical devices -- Quality management systems -- Requirements for regulatory purposes is a voluntary standard, [1] published by International Organization for Standardization (ISO) for the first time in 1996, and contains a comprehensive quality management system for the design and manufacture of medical devices.

  7. Process validation - Wikipedia

    en.wikipedia.org/wiki/Process_Validation

    Process validation is the analysis of data gathered throughout the design and manufacturing of a product in order to confirm that the process can reliably output products of a determined standard. Regulatory authorities like EMA and FDA have published guidelines relating to process validation. [ 1 ]

  8. Independent reviewer - Wikipedia

    en.wikipedia.org/wiki/Independent_reviewer

    The US Food and Drug Administration requires that developers of medical device follow a system of design controls.A key part of this system is design review, defined in 21CFR820.3 section (h) as "a documented, comprehensive, systematic examination of the design to evaluate the adequacy of the design requirements, to evaluate the capability of the design to meet these requirements, and to ...

  9. Design history file - Wikipedia

    en.wikipedia.org/wiki/Design_history_file

    A design history file is a compilation of documentation that describes the design history of a finished medical device.The design history file, or DHF, is part of regulation introduced in 1990 when the U.S. Congress passed the Safe Medical Devices Act, which established new standards for medical devices that can cause or contribute to the death, serious illness, or injury of a patient.