The target analytes are extracted by mixing the sample with water and purge with inert gas (e.g. Nitrogen gas) into an airtight chamber, this is known as purging or sparging. The volatile compounds move into the headspace above the water and are drawn along a pressure gradient (caused by the introduction of the purge gas) out of the chamber.
Gas chromatography-mass spectrometry is a widely used analytical technique for the detection of volatile compounds. Ionization techniques most frequently used in forensic toxicology include electron ionization (EI) or chemical ionization (CI), with EI being preferred in forensic analysis due to its detailed mass spectra and its large library of ...
Gas chromatography (GC) performs the same function as liquid chromatography, but it is used for volatile mixtures. In forensic chemistry, the most common GC instruments use mass spectrometry as their detector. [1] GC-MS can be used in investigations of arson, poisoning, and explosions to determine exactly what was used.
One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
Silylations are core methods for production of organosilicon chemistry. Silanization, while similar to silylation, usually refers to attachment of silyl groups to solids. [1] Silyl groups are commonly used for: alcohol protection, enolate trapping, gas chromatography, electron-impact mass spectrometry (EI-MS), and coordinating with metal complexes.
If the urine screen is positive then another aliquot of the sample is used to confirm the findings by gas chromatography—mass spectrometry (GC-MS) or liquid chromatography - mass spectrometry methodology. If requested by the physician or employer, certain drugs are screened for individually; these are generally drugs part of a chemical class ...
In a typical gas chromatography analysis, isotopic dilution can decrease the uncertainty of the measurement results from 5% to 1%. It can also be used in mass spectrometry (commonly referred to as isotopic dilution mass spectrometry or IDMS), in which the isotopic ratio can be determined with precision typically better than 0.25%.