  1. Results from the WOW.Com Content Network
  2. Cerebrospinal fluid flow MRI - Wikipedia

    en.wikipedia.org/wiki/Cerebrospinal_Fluid_Flow_MRI

    The study of CSF flow became one of Phase-contrast MRI's major applications. The key to Phase-contrast MRI (PC-MRI) is the use of a bipolar gradient. [4] A bipolar gradient has equal positive and negative magnitudes that are applied for the same time duration.

  3. T2*-weighted imaging - Wikipedia

    en.wikipedia.org/wiki/T2*-weighted_imaging

    T2*-weighted imaging of the brain 26 weeks after subarachnoid hemorrhage, showing hemosiderin deposits as hypointense areas. [1] T 2 *-weighted imaging is an MRI sequence to quantify observable or effective T 2 (T2* or "T2-star"). In this sequence, hemorrhages and hemosiderin deposits become hypointense. [2]

  4. Susceptibility weighted imaging - Wikipedia

    en.wikipedia.org/wiki/Susceptibility_weighted...

    Images of CAA collected at 1.5 T. Left, conventional T2* (TE=20 ms), center, SWI processed magnitude image (TE=40 ms) and right, SWI phase image (TE=40 ms) Gradient recalled echo (GRE) imaging is the conventional way to detect hemorrhage in CAA , however SWI is a much more sensitive technique that can reveal many micro-hemorrhages that are ...

  5. Phase contrast magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Phase_Contrast_Magnetic...

    Vastly undersampled Isotropic Projection Reconstruction (VIPR) of a phase contrast (PC) MRI sequence of a 56-year-old male with dissections of the celiac artery (upper) and the superior mesenteric artery (lower). Laminar flow is present in the true lumen (closed arrow) and helical flow is present in the false lumen (open arrow). [1]

  6. Template:Table of MRI sequences - Wikipedia

    en.wikipedia.org/wiki/Template:Table_of_MRI...

    High signal for paramagnetic substances, such as MRI contrast agents [2] Standard foundation and comparison for other sequences T2 weighted: T2: Measuring spin–spin relaxation by using long TR and TE times Higher signal for more water content [1] Low signal for fat in standard Spine Echo (SE), [1] though not with Fast Spin Echo/Turbo Spin ...

  7. Inversion recovery - Wikipedia

    en.wikipedia.org/wiki/Inversion_recovery

    Fluid-attenuated inversion recovery (FLAIR) [2] is an inversion-recovery pulse sequence used to nullify the signal from fluids. For example, it can be used in brain imaging to suppress cerebrospinal fluid so as to bring out periventricular hyperintense lesions, such as multiple sclerosis plaques.

  8. Spin–spin relaxation - Wikipedia

    en.wikipedia.org/wiki/Spin–spin_relaxation

    In MRI, T 2-weighted images can be obtained by selecting an echo time on the order of the various tissues' T 2 s. [8] In order to reduce the amount of T 1 information and therefore contamination in the image, excited spins are allowed to return to near- equilibrium on a T 1 scale before being excited again.

  9. Hyperintensity - Wikipedia

    en.wikipedia.org/wiki/Hyperintensity

    MRI scans showing hyperintensities. A hyperintensity or T2 hyperintensity is an area of high intensity on types of magnetic resonance imaging (MRI) scans of the brain of a human or of another mammal that reflect lesions produced largely by demyelination and axonal loss.