enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Working load limit - Wikipedia

    en.wikipedia.org/wiki/Minimum_breaking_strength

    The current American standard for lifting and handling devices is Reference (1), which provides minimum structural and mechanical design and electrical component selection criteria for ASME B30.20 below-the-hook lifting devices. The provisions in this Standard apply to the design or modification of below-the-hook lifting devices. As such:

  3. Eurocode 1: Actions on structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_1:_Actions_on...

    EN 1991-1-1 gives design guidance and actions for the structural design of buildings and civil engineering works including some geotechnical aspects for the following subjects: Densities of construction materials and stored materials. Self-weight of construction works. Imposed loads for buildings.

  4. Lift slab construction - Wikipedia

    en.wikipedia.org/wiki/Lift_slab_construction

    Lift slab construction (also called the Youtz-Slick Method) is a method of constructing concrete buildings by casting the floor or roof slab on top of the previous slab and then raising (jacking) the slab up with hydraulic jacks. This method of construction allows for a large portion of the work to be completed at ground level, negating the ...

  5. Precast concrete lifting anchor system - Wikipedia

    en.wikipedia.org/wiki/Precast_concrete_lifting...

    The configuration (size, position and quantity) of this reinforcement should be supplemented to the element reinforcement design to ensure for adequate capacity of the lifting design. Lifting design is influenced by the steel / concrete interaction of the specific anchor selected. Different load cases are considered by the lifting design ...

  6. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  7. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. [ 1 ]

  8. Rigging (material handling) - Wikipedia

    en.wikipedia.org/wiki/Rigging_(material_handling)

    A team of riggers design and install the lifting or rolling equipment needed to raise, roll, slide or lift objects such as heavy machinery, structural components, building materials, or large-scale fixtures with a crane, hoist or block and tackle. Rigging comes from rig, to set up or prepare.

  9. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    These load factors are, roughly, a ratio of the theoretical design strength to the maximum load expected in service. They are developed to help achieve the desired level of reliability of a structure [ 6 ] based on probabilistic studies that take into account the load's originating cause, recurrence, distribution, and static or dynamic nature.