Search results
Results from the WOW.Com Content Network
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
pipe size Thread density Thread pitch P Hand-tight engagement [6] Effective thread [6] Overall length L 4 [6] Actual outside diameter D Tap drill; Length L 1 Turns Diameter E 1 Length L 2 Turns Diameter E 2; inch inch −1 inch mm inch inch inch inch inch inch mm inch mm 1 ⁄ 16: 27 0.03703704 0.9407 0.1600: 4.32: 0.28118 0.2611: 7.05: 0.2875 ...
For pipe sizes of NPS 14 inch (DN 350) and greater the NPS size is the actual diameter in inches and the DN size is equal to NPS times 25 (not 25.4) rounded to a convenient multiple of 50. For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is equivalent to DN 350.
The iron pipe size standard came into being early in the 19th century and remained in effect until after World War II. The IPS system was primarily used in the United States and the United Kingdom. In the 1920s, the Copper Tube Size (CTS) standard was combined with the IPS standard.
An elbow is installed between two lengths of pipe (or tubing) to allow a change of direction, usually a 90° or 45° angle; 22.5° elbows are also available. The ends may be machined for butt welding, threaded (usually female), or socketed. When the ends differ in size, it is known as a reducing (or reducer) elbow.
Flexible metallic tubing (FMT; North America) is not the same as flexible metallic conduit (FMC) which is described in US National Electrical Code (NEC) Article 348. FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes.
AN sizes range from -2 (dash two) to -32 in irregular steps, with each step equating to the OD (outside diameter) of the tubing in 1 ⁄ 16-inch increments. Therefore, a -8 AN size would be equal to 1 ⁄ 2-inch OD tube. However, this system does not specify the ID (inside diameter) of the tubing because the tube wall can vary in thickness.
Common sizes are 15 mm and 22 mm. [7] Other sizes include 18 mm, 28 mm, 35 mm, 42 mm, 54 mm, 66.7 mm, 76.1 mm, and 108 mm outside diameters. Tubing in 8 mm and 10 mm outside diameters is called a "micro bore" and is easier to install, although there is a slightly increased risk of blockage from scale or debris.