enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Friction loss - Wikipedia

    en.wikipedia.org/wiki/Friction_loss

    Note that, in approximation, for a given value of flow volume, a step up in duct size (say from 100mm to 120mm) will reduce the friction loss by a factor of 3. Volumetric Flow Q of air at STP where friction loss per unit length Δ p / L (SI kg / m 2 / s 2 ) is, resp., 0.082, 0.245, and 0.816., for selected Nominal Duct Sizes [ 19 ] in smooth ...

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  5. Pressurisation ductwork - Wikipedia

    en.wikipedia.org/wiki/Pressurisation_ductwork

    There are two means of providing fire-resistance rated ductwork: Inherently fire-resistant, or proprietary factory assembled ducts which are made of sheet metal shells filled with mixtures of rockwool, fiber and silicon dioxide

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 scfm when C v = 1.0, 2 psia input).

  7. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    Rectangular cement plant duct stiffeners are 15 to 20% times duct plate weight. Power plant ductwork is often larger. Power plant ductwork is usually rectangular, with stiffener weights of 50% (or more) times duct plate weight. (this is based on personal experience, and my vary with loads, duct size, and industry standards)

  8. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    where the pressure loss per unit length ⁠ Δp / L ⁠ (SI units: Pa/m) is a function of: ρ {\displaystyle \rho } , the density of the fluid (kg/m 3 ); D H {\displaystyle D_{H}} , the hydraulic diameter of the pipe (for a pipe of circular section, this equals D ; otherwise D H = 4A/P for a pipe of cross-sectional area A and perimeter P ) (m);

  9. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    where is in absolute pressure units and is in absolute temperature units (i.e., either kelvins or degrees Rankine). This is only valid when at a pressure and temperature close to standard conditions. For non-ideal gasses (most gasses) a compressibility factor "Z" is introduced to allow for non-ideality. To introduce the compressibility factor ...