The "elution time" of a solute is the time between the start of the separation (the time at which the solute enters the column) and the time at which the solute elutes. In the same way, the elution volume is the volume of eluent required to cause elution. Under standard conditions for a known mix of solutes in a certain technique, the elution ...
Elution of the adsorbed proteins was commonly performed with the eluent flow in the reverse direction; that is, as a conventional packed bed, in order to recover the adsorbed solutes in a smaller volume of eluent. However, a new generation of EBA columns has been developed, which maintain the bed in the expanded state during this phase ...
In any form of chromatography, the rate at which the solute moves down the column is a direct reflection of the percentage of time the solute spends in the mobile phase. To achieve separation in either elution or displacement chromatography, there must be appreciable differences in the affinity of the respective solutes for the stationary phase.
As the temperature of the elution increased, when the chains behave in a more hydrophobic manner, the elution times increased for each of the analytes for the given range. The trend generally applies over the entire temperature range, but there is a flattening of the curve before 25 °C and after 32 °C (the approximate LCST for this experiment).
In the pharmaceutical industry, drug dissolution testing is routinely used to provide critical in vitro drug release information for both quality control purposes, i.e., to assess batch-to-batch consistency of solid oral dosage forms such as tablets, and drug development, i.e., to predict in vivo drug release profiles. [1]
Proteins can coordinate metal ions on their surface and it is possible to separate proteins using chromatography by making use of the difference in their affinity to metal ions. This is termed as immobilized metal ion affinity chromatography (IMAC), as originally introduced in 1975 under the name metal chelate affinity chromatography. [ 3 ]
Using this method, DNA fragments can be recovered from a particular region of agarose or polyacrylamide gels. The gel piece containing the fragment is excised (cut out from the whole gel) and placed in a dialysis bag with buffer.
These methods are based on gel filtration chromatography, [2] also called molecular sieve chromatography, which is a form of size-exclusion chromatography. Desalting and buffer exchange are two of the most common gel filtration chromatography applications, and they can be performed using the same resin.