enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  3. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  4. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    Impression tonometry (also known as indentation tonometry) measures the depth of corneal indentation made by a small plunger carrying a known weight. The higher the intraocular pressure, the harder it is to push against and indent the cornea. For very high levels of IOP, extra weights can be added to make the plunger push harder. [14]

  5. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma . [ 1 ]

  6. Corneal pachymetry - Wikipedia

    en.wikipedia.org/wiki/Corneal_pachymetry

    Corneal pachymetry is the process of measuring the thickness of the cornea.A pachymeter is a medical device used to measure the thickness of the eye's cornea.It is used to perform corneal pachymetry prior to refractive surgery, for Keratoconus screening, LRI surgery [1] and is useful in screening for patients suspected of developing glaucoma among other uses.

  7. Intraocular lens power calculation - Wikipedia

    en.wikipedia.org/wiki/Intraocular_lens_power...

    The aim of an accurate intraocular lens power calculation is to provide an intraocular lens (IOL) that fits the specific needs and desires of the individual patient. The development of better instrumentation for measuring the eye's axial length (AL) and the use of more precise mathematical formulas to perform the appropriate calculations have significantly improved the accuracy with which the ...

  8. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Visual acuity with Near chart without correctors Visual acuity with eye chart at Near 15.7 inches (400 mm) and without (sc: Latin sine correctore) correctors (spectacles); Ncc is with (cc: Latin cum correctore) correctors. See Visual_acuity#Legal_definitions: VA OS Left visual acuity VA OD Right visual acuity VDU Visual display unit VF Visual field

  9. Effects of long-term contact lens wear on the cornea - Wikipedia

    en.wikipedia.org/wiki/Effects_of_long-term...

    Long-term contact lens use can lead to alterations in corneal thickness, stromal thickness, curvature, corneal sensitivity, cell density, and epithelial oxygen uptake. . Other structural changes may include the formation of epithelial vacuoles and microcysts (containing cellular debris), corneal neovascularization, as well as the emergence of polymegethism in the corneal endoth