The second category of furnace is the forced-air having atmospheric burner style with a cast-iron or sectional steel heat exchanger. Through the 1950s and 1960s, this style of furnace was used to replace the big, natural draft systems, and was sometimes installed on the existing gravity duct work.
Ideally, a room will have both heating and cooling registers. In practice, cost considerations usually require that heating and cooling be provided by the same register. In such cases, heating most often takes precedence over cooling, and registers are usually found close to the floor. [7] For heating purposes, a floor register is preferred.
For example, a conventional heat pump system used to heat a building in Montana's −57 °C (−70 °F) low temperature or cool a building in the highest temperature ever recorded in the US—57 °C (134 °F) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air ...
A steam heating system takes advantage of the high latent heat which is given off when steam condenses to liquid water. In a steam heating system, each room is equipped with a radiator which is connected to a source of low-pressure steam (a boiler). Steam entering the radiator condenses and gives up its latent heat, returning to liquid water.
The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams. FCUs ...
Efficiency is optimised by changing the design of the system on both large and small scales. Heat pumps [7] and evaporative cooling [8] are efficient alternatives to traditional systems, however they may be more expensive or harder to implement. The job of an MEP engineer is to compare these requirements and choose the most suitable design for ...
SYSTEM REQUIREMENTS. Mobile and desktop browsers: Works best with the latest version of Chrome, Edge, FireFox and Safari. Windows: Windows 7 and newer Mac: MacOS X and newer Note: Ad-Free AOL Mail ...
A duct system often begins at an air handler. The blowers in the air handler can create substantial vibration, and the large area of the duct system would transmit this noise and vibration to the inhabitants of the building. To avoid this, vibration isolators (flexible sections) are normally inserted into the duct immediately before and after ...