  2. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    The digits following the letter codes indicate the difference in phase angle between the windings, with HV winding is taken as a reference. The number is in units of 30 degrees. For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding.

  3. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    The source (generator or sub-network) must have equal root-mean-square voltage, frequency, phase sequence, phase angle, and waveform to that of the system to which it is being synchronized. [1] Waveform and phase sequence are fixed by the construction of the generator and its connections to the system.

  4. Synchroscope - Wikipedia

    en.wikipedia.org/wiki/Synchroscope

    If two electrical networks operating at two different phase angles were to be connected to each other, a fault similar to a short circuit would occur, presenting a hazard of damage to the generator or other equipment. The position (as opposed to rotation) of the pointer on a synchroscope indicates the phase angle between the two systems.

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    The phase angle difference between voltage and current of each phase is not necessarily 0 and depends on the type of load impedance, Z y. Inductive and capacitive loads will cause current to either lag or lead the voltage. However, the relative phase angle between each pair of lines (1 to 2, 2 to 3, and 3 to 1) will still be −120°.

  7. Phasor - Wikipedia

    en.wikipedia.org/wiki/Phasor

    Phasor notation (also known as angle notation) is a mathematical notation used in electronics engineering and electrical engineering.A vector whose polar coordinates are magnitude and angle is written . [13] can represent either the vector (⁡, ⁡) or the complex number ⁡ + ⁡ =, according to Euler's formula with =, both of which have magnitudes of 1.

  8. Constellation diagram - Wikipedia

    en.wikipedia.org/wiki/Constellation_diagram

    A 'signal space diagram' is an ideal constellation diagram showing the correct position of the point representing each symbol. After passing through a communication channel, due to electronic noise or distortion added to the signal, the amplitude and phase received by the demodulator may differ from the correct value for the symbol. When ...

  9. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...